TECHNICAL DATA
Heating element resistance heater
Temperature safety cut-out to protect against overheating in case of fan failure,
automatic reset
Heater body anodised extruded aluminium profile
Surface temperature max. +75°C 400W
Axial fan, ball bearing Airflow, free flow 45m3/h 50Hz or 54m3/h 60Hz
service life 50,000h at +25°C +77°F
Connection internal connection terminal 1.5mm2 with strain relief,
clamping torque 0.8Nm max.
Connection casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 60715
Fitting position vertical airflow air outlet up
Operating/Storage temperature -45 to +70°C -49 to +158°F
Operating/Storage humidity max. 90% RH non-condensing
Protection type/Protection class IP20 / I earthed
Note other voltages on request
Art. No. Operating voltage Heating capacity Pre-fuse T time delay Length L Weight approx. Approvals
04640.0-00 230VAC, 50/60Hz 250W 2A 182mm 1.1kg VDE UL File No. E1500571 GOST TR
04641.0-00 230VAC, 50/60Hz 400W 4A 222mm 1.4kg VDE UL File No. E1500571 GOST TR
04640.9-00 120VAC, 50/60Hz 250W 4A 182mm 1.1kg VDE UL File No. E1500571 GOST TR
04641.9-00 120VAC, 50/60Hz 400W 5A 222mm 1.4kg VDE UL File No. E1500571 GOST TR