TECHNICAL DATA
Heating element high performance cartridge
Temperature safety cut-out to protect against overheating in case of fan failure,
automatic reset
Heater body extruded aluminium profile
Axial fan, ball bearing airflow 160m3/h, free flow,
service life 50,000h at +25°C +77°F
Connection 2-pole max. 2.5mm2, clamping screw with strain relief,
torque 0.8Nm max.
Casing plastic according to UL94 V-0, black
Mounting clip for 35mm DIN rail, EN 60715 or screw fixing M6
Fitting position vertical airflow air outlet up – other fitting positions possible
Dimensions 182 x 160 x 99mm
Weight approx. 1.5kg
Operating1/Storage temperature -45 to +70°C -49 to +158°F
Operating/Storage humidity max. 90% RH non-condensing
Protection type/Protection class IP20 / II double insulated
Note other heating capacities from 200W up available on request
1 Operating temperature of heater with integrated hygrostat: 0 to +60°C +32 to +140°F
Art. No. Model Operating voltage Heating capacity Pre-fuse T time-delay Setting range2 Approvals
13051.0-00 Fan Heater with thermostat 230VAC, 50/60Hz 950W 5A 0 to +60°C VDE UL File No. E234324 GOST TR
13051.0-02 Fan Heater with hygrostat 230VAC, 50/60Hz 950W 5A 65% RH, factory-set VDE UL File No. E234324 GOST TR
13059.9-00 Fan Heater with thermostat 120VAC, 50/60Hz 950W 10A +32 to +140°F - UL File No. E234324 GOST TR
2 Switch temperature difference 7K ±4K tolerance